CTS Thermal Shock Test System Type TSS -70/130 Two Chamber version
User benefits
High rate of change of temperature
High performance, reliable and durable
Built-in CTS-Controller
Compliant with CE and EMC standards
Environmental friendly refrigerants
Ergonomically designed
Meets international thermal shock test standards
System includes
Door with window
CTS-Terminal integrated into the door
Potential-free contact for malfunction signal
RS-232 interface
Software controlled min/max temperature limiter
1 stainless steel shelf
1 x 50 mm Ø entry port with cap
Lockable door
Low-noise refrigerating unit
Operating instructions
Technical specification
Temperature tests:
Temperature range of the Hot Chamber
+50°C to +200°C.
Temperature range of the Cold Chamber
-80°C to –10°C.
Temperature fluctuation under
stabilised conditions
+ 1°C temporally.
Temperature change rate for
thermal shock-tests
Up to 100ºC / minute.
Test Load
Maximum 20 kg
Stabilisation time with10 kg IC’s
> 15 Minutes
All figures are values obtained at an ambient temperature of +25ºC, cooling water temperature of +18°C and nominal voltage 400V/50 Hz, without test specimens, radiation or accessories.
Dimensions:
Test space capacity
130 litres
Test space
480 x 660 x 410 mm (W x D x H)
Overall dimensions
870 x 2350 x 1960 mm (W x D x H*)
*2540 mm with spindle
Installation and operation:
Nominal voltage
400 VAC +6/-10 %, 3Ø+N, 50 Hz
Nominal power
Approximately 15 kW
Nominal current
Approximately 30 A
Mains protection on site
32 A (slow-blow fuse)
System protection class
IP 20
Plug
Cekon 32 A
Cooling water connection
Inlet R ¾” female thread.
Outlet R ¾” female thread
Overpressure 3 to 6 bar
Differential pressure > 2.5 bar
Water temperature up to +20 ºC
Consumption: maximum 1.5 m³/h
at Δt = 10°K
Acoustic pressure level
< 70 dB (A) measured in a distance of 1 metre from the front.
Weight
Compressed air connection
Approximately 950 kg
¼” AG
Design:
Refrigeration unit
Water-cooled, low noise fully hermetic refrigeration unit, continuous performance adjustment via electronic monitoring and control system.
Chloride free refrigerants are used in a hermetically sealed refrigeration cycle. Freon R404 A
Heating
Stainless steel elements with over- temperature protection.